Property Data

NYLON 46

Glass Fiber Reinforced
Heat Stabilized
Unreinforced and Glass Fiber Reinforced
Flame Retardant
Heat Stabilized

For additional information on Nylon 46,
call DSM Engineering Plastics at 800-333-4237 or 812-435-7702.


Chart below covers grades that are heat stabilized, glass fiber reinforced Nylon 46 resins,
providing low creep and high stiffness and strength characteristics.

Typical Properties Unit ASTM Test TW200F3 TW200F6 TW200F8 TW241F10
Glass Fiber Content % wt   15 30 40 50
Specific Gravity g/cc D792 1.30 1.41 1.51 1.62
Melting Point °F D3417 563 563 563 563
Linear Mold Shrinkage 1/8" average section in/in D955 0.005-0.009 0.004-0.006 0.004-0.005 0.002-0.004
Water Absorption Equilibrium % - 3.1 2.6 2.2 1.8
Impact Resistance, Izod - Notched (1/8")
dry ft-lb/in D256 1.6 2.0 2.1 2.2
conditioned ft-lb/in D256 2.4 3.5 3.6 3.7
Tensile Strength
dry psi D638 21,800 30,000 32,000 34,000
conditioned psi D638 14,500 17,000 20,300 23,200
Tensile Elongation
dry % D638 3 4 3 3
conditioned % D638 - 8 6 4
Tensile Modulus
dry psi x 105 D638 8.41 13.00 18.30 23.20
conditioned psi x 105 D638 4.06 6.50 10.60 14.50
Flexural Strength
dry psi D790 31,900 43,000 43,500 50,750
conditioned psi D790 18,900 27,000 29,000 29,000
Flexural Modulus
dry psi x 105 D790 7.98 12.0 17.0 20.3
conditioned psi x 105 D790 3.92 6.60 10.0 13.0
HDT @ 264 psi °F D648 480 545 545 545
Peak Temperature (1 min) °F   >445 >480 >480 >480
Continuous Use Temperature (5000 hours) °F   330 330 330 330

 

Chart below covers grades that are heat stabilized, flame retardant Nylon 46 resins,
designed for electrical applications, UL 94 V-0 @ 0.8 mm.

Typical Properties Unit ASTM Test TE351 TE250F3 TE250F6 TE250F9
Glass Fiber Content % wt   0 15 30 45
Specific Gravity g/cc D792 1.35 1.47 1.68 1.82
Melting Point °F D3417 563 563 562 562
Linear Mold Shrinkage 1/8" average section in/in D955 0.018-0.020 0.006-0.009 0.004-0.006 0.002-0.004
Water Absorption Equilibrium % - 2.4 2.1 1.6 1.2
Impact Resistance, Izod - Notched (1/8")
dry ft-lb/in D256 1.1 0.5 1.3 1.9
conditioned ft-lb/in D256 2.5 - 1.9 2.2
Tensile Strength
dry psi D638 8,300 16,500 25,400 29,000
conditioned psi D638 5,500 10,000 18,100 21,800
Tensile Elongation
dry % D638 15 8 2.5 2.1
conditioned % D638 30 20 3.5 3.0
Tensile Modulus
dry psi x 105 D638 3.90 10.00 18.10 25.00
conditioned psi x 105 D638 2.50 5.50 11.60 17.00
Flexural Strength
dry psi D790 34,000 27,000 37,700 42,500
conditioned psi D790 6,000 17,500 27,600 36,300
Flexural Modulus
dry psi x 105 D790 3.80 11.25 16.00 22.00
conditioned psi x 105 D790 1.30 5.50 12.00 16.00
HDT @ 264 psi °F D648 320 480 545 545
Coefficient of Linear Thermal Expansion D696 in/in/°F x 10 10   2 2
UL Flame Class 1/32" UL94 - V-0 V-0 V-0 V-0
Comparative Tracking Index - volts 300   250 275
Volume Resistivity
dry IEC 250 ohm-cm 1016 - 1015 1015
conditioned IEC 250 ohm-cm 109   1010 1010
Surface Resistivity
dry IEC 259 ohm >1016   1016 1016
conditioned IEC 250 ohm 1014   1014 1014
Peak Temperature (1 min) °F   >445 >480 >480 >480
Continuous Use Temperature (5000 hours) °F   330 330 330 330